Power & Physical Infrastructure
Power Requirements
| Component |
Power Draw |
Notes |
| HYDRA Body (compute) |
1 kW per unit |
Dedicated circuit recommended, on-site compute only |
| Access Point (via PoE) |
25.5 W per AP |
Provided through PoE+ switch |
| Receiver Workstations |
150 W per unit |
Mac Mini ~40 W; Dell ~150 W |
| Display Screens |
Per manufacturer spec |
|
| Total (on-site compute) |
~1.5 kW per single-field deployment |
Excluding displays |
| Total (remote compute) |
~200 W per field |
AP + switch + workstations only |
- Outlet type: standard venue power
- UPS recommended for compute units
Rack & Mounting
| Component |
Requirement |
| Network Gear |
6U rack space (router, switch, PoE injector), HYDRA-supplied network only |
| Compute (if racked) |
19U rack, 24-inch depth minimum, on-site compute only |
| Compute (standalone) |
HYDRA Body can be placed on floor or table |
| Remote Compute |
No rack or floor space required for compute |
| AP Mounting |
Non-metallic pole or ceiling mount, adjustable 3–4 m, centered over play area |
| Cable Pathway |
CAT6a from network gear to AP mount point; ethernet to each workstation |
Play Area
| Attribute |
Requirement |
| Dimensions |
Up to 16 m diameter (200 m²) per field |
| Floor Surface |
Flat, hard surface (no deep carpet) |
| Ceiling Height |
4 m minimum clearance |
| Lighting |
500–750 lux, 4000–5000 K color temperature, uniform, non-flickering |
| Line of Sight |
Clear path from AP to all play positions (no obstructions above head height) |
Exhibitor-Supplied Equipment
Measured on a 280-stand expo in October 2026, where most equipment belonged
to exhibitors. Three power-related causes accounted for a large share of
repeat faults, and all three are settled before the doors open rather than
during the run.
| Finding |
What to do |
| Displays and computers left in standby or sleep went dark during opening hours, and one computer slept every 15 minutes |
Disable standby and sleep at the device. Do not work around it each morning |
| A stand whose power cable was within visitor reach was reported repeatedly, because the computer dropped out whenever the cable was touched |
Strain-relieve and route out of reach; treat a reachable cable as a defect |
| One installation required all three of its display cables to be seated before the computer was given power, in that order |
Record the cabling order per stand where it matters |
A stand with its own computer is a single point of failure that no UPS of
ours covers. Where the installation matters, ask the exhibitor for a UPS on
their own equipment, or expect the stand to drop with the circuit.